Honeywell RTH6360 Thermostat Wiring Diagram

Honeywell RTH6360 Thermostat Wiring Diagram

Honeywell RTH6360 Thermostat Wiring Diagram

5/5 (1👤)
🌡️ HVAC & Water Heating 🧮 3 schematics
★Rate It★

How many stars do you give this diagram?

UWP wall plate

Plate terminals and the old thermostat's wire letters.

UWP wall plate
EQUIPMENT WIRESEQUIPMENT WIRESTHERMOSTATCONNECTORSL/AASO/BYAUXW2Y2EGWCKURURcR WIRES1 WIRE2 WIRESR WIRES1 WIRE2 WIRESY · Y1 · MY2G · FC · C1 · X · BC · X · BW2W · W1 · HR · RH · 4 · VRc (or R)R · RH · RcF (not connected)O · B · HW · W1 · W2E · X · X2R · V · VR

Terminals and components · 10

  • R · Rc (24 V)
  • Common
  • Fan
  • Cooling / compressor
  • Heating
  • Heating stage 2

About This Diagram

This diagram is redrawn from pages 12–13 of the Honeywell RTH6360 Thermostat manual, and we offer it completely free and in English. We have also categorized it in the Thermostats (HVAC & Water Heating) section on Diagramverse, and it has been rated by 1 user with an average rating of 5.0. If you have any specific questions about the Honeywell RTH6360 Thermostat Wiring Diagram, we suggest checking the Frequently Asked Questions (FAQs) section.

Printable Honeywell RTH6360 Wiring Diagrams

Conventional · R and Rc

1 / 3
Honeywell RTH6360 Thermostat Wiring Diagram – Conventional · R and Rc
Honeywell RTH6360 Thermostat Wiring Diagram – Conventional · one R wire
Honeywell RTH6360 Thermostat Wiring Diagram – Heat pump

Wiring Instructions

Before you start

The Honeywell RTH6360 is a battery-powered thermostat for 24 V systems: gas, oil or electric forced air, hot water fan coils, boilers, steam and single-compressor air-to-air heat pumps. It does not work with 120/240 V line-voltage electric heat. If your old thermostat has thick black wires joined with wire nuts, or is marked 120 V or higher, stop. This thermostat will not work on that system.

You need a small flat-head screwdriver, a Phillips screwdriver, a pencil and a level. You may also need a wire stripper, needle-nose pliers and a drill with a 7/32 in bit. The box includes the UWP wall plate, screws, anchors and wire labels. Have two AA alkaline batteries ready. They always power the thermostat, even when a C wire is connected. Reuse the existing thermostat cable if you can. If you run new cable, use standard low-voltage thermostat wire (18 AWG is typical) and follow your equipment instructions and local code.

Call a licensed HVAC contractor if you find wires on terminals this thermostat does not support, a heat pump with both V and VR wires, or a heat pump with separate Y1, W1 and W2 wires.

Identify your diagram variant

  • Conventional · one R wire: a furnace, boiler or air conditioner with a single R, RH or Rc wire. Set the R switch up.
  • Conventional · R and Rc: separate heating and cooling transformers, so you have two R wires. Set the R switch down.
  • Heat pump: the outdoor unit both heats and cools, usually with an O, B or O/B wire. Set the R switch up.

Step-by-step wiring

  1. Turn off power to the heating and cooling system at the breaker or at the equipment switch. To confirm it's off, set the old thermostat to call for heat or cooling. If nothing starts within 5 minutes, the power is off.
  2. Remove the old faceplate without disconnecting any wires. Take a clear photo that shows each wire and the letter of its terminal.
  3. Remove any jumpers between terminals, for example between R and Rc. The RTH6360 does not need them, and they don't count as wires.
  4. Write down which terminals have wires and their colors, and count the R-type wires: R, RH and Rc. Note any wire on L/A, S or U. The RTH6360 does not support these terminals, so a fault alert wire stays disconnected.
  5. Release each wire and label it with the letter of its old terminal, not its color. Wrap the wires around a pencil so they can't fall into the wall, then remove the old wall plate.
  6. Feed the wires through the back of the UWP, with at least 1/4 in of bare copper on each one. Level the plate, mark the holes, drill, and tap the anchors in until they are flush.
  7. Set the R switch: up for one R wire, down for two. With two wires, put Rc on the Rc terminal and R or RH on R. If your old thermostat had both R and RH, connect the R wire to Rc and the RH wire to R.
  8. Connect the remaining wires, one per terminal. Press each tab and push the wire into the inner hole: G to G, Y or Y1 to Y, W or W1 to W, C to C, plus Y2, W2, O/B, AUX and E if you have them. Tug each wire gently to check it holds.
  9. On a heat pump, the backup heat wire goes on AUX or E, never on W. If you had separate O and B wires, B goes on C. If C already has a wire, stop and call a contractor. On a conventional system with two C or C1 wires, tape each one separately and leave both disconnected.
  10. Check the wiring against your photo. Mount the UWP with all three supplied #8 1-1/2 in screws and close the door.
  11. Insert two AA alkaline batteries and snap the thermostat firmly onto the UWP.

Testing and start-up

Turn the power back on and set the date, clock format and time. Then work through System Setup: 200 for system type, 205 for equipment type, 218 for O or B on a heat pump, 220 for cooling or compressor stages, 221 for heat or backup heat stages, and 300 for manual or automatic changeover.

Test each function. In Heat, raise the setpoint above room temperature and the furnace, boiler or heat pump should start. In Cool, set it below room temperature and the compressor and fan should run. Set Fan to On to confirm the fan runs on its own. Heat On or Cool On may flash for up to 5 minutes while compressor protection is active. On a heat pump, confirm warm air in Heat and cool air in Cool, and test Em Heat if you have backup heat. If you have a meter, R to C at the wall plate should read about 24 V AC.

Safety notes

  • The thermostat circuit is 24 V, but the furnace or air handler has 120/240 V inside. Keep the power off while wiring, and don't open equipment panels unless you are qualified.
  • Keep bare wire ends apart. A short from R to C or to another terminal can blow the control board fuse or damage the transformer.
  • If the old thermostat has a sealed mercury tube, don't put it in the trash. Take it to a hazardous waste or recycling site, and dispose of the RTH6360 the same way at the end of its life.

Troubleshooting

Symptom Probable Cause What to Check
The screen is completely blank after installation The batteries are missing, dead or in backwards. The C wire does not power this thermostat. Install two fresh AA alkaline batteries in the back of the thermostat, the right way round, and snap it firmly back onto the UWP.
The screen works but nothing heats or cools The system has no power, the furnace door switch is open, or the R wire is loose Check the breaker and the equipment power switch, and make sure the furnace door is closed securely. Tug the R wire in its terminal. With a meter, R to C should read about 24 V AC.
Heat works but cooling does not, or the other way round The R switch is in the wrong position for your number of R wires With one R wire, the R switch must be up. With two R wires, it must be down, with Rc on the Rc terminal and R or RH on the R terminal.
The heat pump blows cold air in Heat and warm air in Cool Reversing valve setting 218 doesn't match the O/B wire, or system type 200 is wrong Set 200 to Heat Pump. If the valve energizes in cooling, set 218 to O; if it energizes in heating, set 218 to B.
I can't select Cool mode Cooling stages are set to 0, or the system type is set to heat only In System Setup, set 220 to 1 or 2 to match your equipment, and check that 200 matches your system.
The furnace heats but the blower never comes on Equipment type 205 doesn't match the furnace, or the G wire is loose Set 205 to your equipment, for example 4 for electric forced air. Check that the G wire is firmly seated in G, and test with Fan set to On.
Backup or emergency heat never comes on with the heat pump The auxiliary heat wire is on W, or backup heat stages are set to 0 Move the wire to AUX or E, never W. Set 221 to 1, then test Em Heat mode.
The system runs nonstop, or stopped dead with a blown fuse right after install An old jumper was left in place, bare wire ends are touching, or a wire is on the wrong terminal Turn off the power. Remove any jumpers, trim and reseat the wires so no copper touches, and compare each wire against your photo. Then check the fuse on the control board.
The second compressor or heating stage never runs The Y2 or W2 wire is not connected, or stages are set to 1 Confirm Y2 or W2 is seated, then set 220 or 221 to 2 on conventional systems. A heat pump supports only one compressor stage.
Heat On or Cool On flashes and nothing starts Compressor protection delay is active Wait 5 minutes. If the equipment still doesn't start, check the Y wire and the system power.

Frequently Asked Questions (FAQs)


How do I wire a Honeywell RTH9585WF?
You wire the RTH9585WF the same basic way: label each old wire with the letter of the terminal it came from and connect it to the terminal with the same letter. It is a different model, though: a Wi-Fi touchscreen with its own wall plate and setup, and Wi-Fi thermostats generally need a C wire for constant power. Follow the installation guide for that model rather than this RTH6360 diagram. The basic precautions are the same: power off, 24 V systems only, and remove any jumpers.

What color wires go where on a Honeywell thermostat?
Go by the terminal letters, not the colors. The usual convention is red for R, white for W, yellow for Y, green for G and blue or black for C, but installers don't always follow it, and old wires fade. Before you disconnect anything, photograph the old terminals and label each wire with the letter it was attached to. Then connect each wire to the matching letter on the UWP, using the alternate names shown on the diagram if your old labels differ.

Do all Honeywell thermostats use the same wiring?
No. The terminal letters follow the same industry conventions, but models differ in which terminals they offer, how they are powered and which systems they support. The RTH6360 runs on AA batteries, has an R switch for one or two R wires, supports one heat pump compressor stage, and does not support L/A, S or U. Wi-Fi and more advanced models may need a C wire or offer extra terminals. Always use the wiring diagram for your exact model.

Does the RTH6360 need a C wire?
No, the RTH6360 does not need a C wire for power. It runs on two AA alkaline batteries, which are always required. If your system has a single C or C1 wire, connect it to the C terminal anyway. On a heat pump with separate O and B wires, the B wire uses the C terminal. On a conventional system with two C or C1 wires, tape each one separately and leave them unconnected.

Which R switch position do I need?
Use the up position if you have one R wire and the down position if you have two. One R, RH or Rc wire means a single transformer, so the switch goes up and links R and Rc inside the plate. Two R wires, usually R or RH plus Rc, mean separate heating and cooling transformers, so the switch goes down to keep them apart. Heat pumps always use the up position.

Can I use the RTH6360 with electric baseboard heaters?
No. Baseboard and other line-voltage heaters run at 120 or 240 V, usually with thick wires joined by wire nuts, and this thermostat works only on 24 V control circuits. Connecting it to line voltage would destroy it and create a shock and fire hazard. Electric forced-air furnaces with a 24 V thermostat circuit are supported: choose the electric forced air setting in function 205.

Can the RTH6360 control a two-stage system?
Yes, partly. On conventional systems it can control up to two cooling stages through Y and Y2, and up to two heating stages through W and W2. On a heat pump it controls only one compressor stage, plus one auxiliary or emergency heat stage on AUX or E. Set functions 220 and 221 to match. If your heat pump has Y1, W1 and W2 wires, have a contractor review the system.

What should I do with a wire on the L/A, S or U terminal?
Leave it disconnected and insulated, because the RTH6360 does not support these terminals. L/A is the heat pump fault alert, and that alert will not appear on this model. If you need it, ask a contractor about a model that supports it. Wires on S or U usually go to sensors or accessories that this thermostat cannot use. If an unsupported wire controls something important, consult a professional before you proceed.

Do I keep the jumper between R and Rc?
No, remove any jumper before installing the RTH6360. A jumper is a small metal staple or short wire linking two terminals on the old thermostat. On this model, the R switch does that job internally: in the up position it joins R and Rc for single-transformer systems. Don't count a jumper as one of your wires when you decide on the switch position.

Related Product Diagrams

Go up